Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
JCPSP-Journal of the College of Physicians and Surgeons Pakistan. 2017; 27 (5): 271-274
in English | IMEMR | ID: emr-187984

ABSTRACT

Objective: To assess the diagnostic accuracy of CT scan in detecting paranasal sinus fungal infections


Study Design: Cross-sectional, observational study


Place and Duration of Study: Department of Radiology, Ziauddin University Hospital, Karachi, from April to September 2014


Methodology: Patients with clinical suspicion of fungal sinusitis were included in this study. Patients with already diagnosed or history of recurrent fungal infections were excluded. All these patients underwent CT scan examination of paranasal sinuses. Findings were recorded. Final diagnosis was based on smear analysis for fungal culture. Accuracy analysis was conducted for CT diagnosis using smear analysis as the gold standard. Kappa analysis was conducted to determine agreement


Results: Out of the 120 patients, 71 [59%] were male. The sensitivity, specificity, positive predictive value and negative predictive value of CT were 96.19%, 93.33%, 99.01%, 77.77%, respectively. The diagnostic accuracy was 95.83%. Kappa statistics showed 82% agreement beyond chance


Conclusion: CT scan is highly accurate in diagnosing and characterizing fungal infection of paranasal sinuses. It also determines the extent of disease which eventually aids in deciding the surgical approach to be used

2.
Pakistan Journal of Medical Sciences. 2016; 32 (2): 385-388
in English | IMEMR | ID: emr-178652

ABSTRACT

Objective: To study the diagnostic accuracy of Ultrasound B scan using 10 MHz linear probe in ocular trauma


Methods: A total of 61 patients with 63 ocular injuries were assessed during July 2013 to January 2014. All patients were referred to the department of Radiology from Emergency Room since adequate clinical assessment of the fundus was impossible because of the presence of opaque ocular media. Based on radiological diagnosis, the patients were provided treatment [surgical or medical]. Clinical diagnosis was confirmed during surgical procedures or clinical follow-up


Results: A total of 63 ocular injuries were examined in 61 patients. The overall sensitivity was 91.5%, Specificity was 98.87%, Positive predictive value was 87.62 and Negative predictive value was 99%


Conclusion: Ultrasound B-scan is a sensitive, non invasive and rapid way of assessing intraocular damage caused by blunt or penetrating eye injuries

SELECTION OF CITATIONS
SEARCH DETAIL